AeroVac V2

Recommended Use

  • Ideal for use in jewelry manufacturing
  • Ideal for use in optical laboratories
  • Ideal for use in educational and classroom settings

AeroVac V2

Cartridge Dust Collector
  • Whisper quiet operation (built-in silencer)
  • Bagless high-performance system
  • Durable single Brushless motor

The AeroVac V2 Cartridge Dust Collector offers high-pressure dust collection with multi-stage filtration. Ideal for
multiple users, the AeroVac V2 features a durable, maintenance-free Brushless
industrial motor along with a large debris storage tray for easy clean up.
Available with your choice of single 2″, 3″ or 4″ inlet. Mechanical cartridge seal is included.

Benefits

  • Plug and play design
  • Small footprint
  • 99.97% efficient at 0.3µm.
  • CE and CSA-certified

Features

  • Whisper quiet operation (built-in silencer)
  • Bagless high-performance system
  • Durable single Brushless motor

Options

  • Your choice of 2″, 3″, or 4″ single side inlet
Product Number Pressure CFM Volts/Phase/Hz Amps Shipping Weight Width Height Depth Noise (dB) Max Debris Capacity (in3) Filter Sequence Filter Efficiency
1-0047-0712
(Single Brushless motor/Single 2″ inlet)
54″ WC 220 120/1/60 12 81 lbs
(37 kg)
14″ 17″ 26″ 63dB(A) 225 • Filter Pad F069-82
• 10.39″ HEPA Cartridge F032
• MERV 4
• MERV 17
1-0047-0713
(Single Brushless motor/Single 3″ inlet)
54″ WC 220 120/1/60 12 81 lbs
(37 kg)
14″ 17″ 26″ 63dB(A) 225 • Filter Pad F069-82
• 10.39″ HEPA Cartridge F032
• MERV 4
• MERV 17
1-0047-0714
(Single Brushless motor/Single 4″ inlet)
54″ WC 220 120/1/60 12 81 lbs
(37 kg)
14″ 17″ 26″ 63dB(A) 225 • Filter Pad F069-82
• 10.39″ HEPA Cartridge F032
• MERV 4
• MERV 17

Learn how to get the most out of your Quatro Air unit and troubleshoot common problems. You can also download the owner’s manual for this unit for technical details and instructions.

Owner’s manual

Quatro Air AeroVac V2 Dust Collector Owner’s Manual

How to Set Up Your Unit for the First Time

Introduction

Congratulations! You are now owner of a Quatro Air AeroVac V2 Dust Collector, an advanced effective purifier designed specifically for the human respiratory system. You can expect a noticeable improvement in air quality as the unit begins the process of reducing microscopic airborne particulate, dust, harmful gases, smoke, and pollen etc.

Safety Precaution

Keep all fastening hardware tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which filters are installed &replaced. All filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do not use any two-wire electrical prong adapters to defeat proper grounding. If servicing the unit, be careful not to touch the motor as soon as it has been turned off. It is hot and can cause injury.

IMPORTANT: Ensure power supply is unplugged during maintenance or filter service

Pre Start-Up Checklist

  1. Upon arrival, inspect unit for either visible or concealed damage. Damage should be immediately reported to the
    transport company.
  2. All filters are present and are correctly installed prior use
  3. Labels and serial numbers are present for future identification
  4. Verify that power supply is compatible with equipment. Check the unit is plugged into a grounded receptacle

Start-Up

WARNING: Do not operate unit until you’ve confirmed all filters have been installed

  1. Place the unit in the desired area for use. Ensure all filters are installed (remove all plastic wrapping)
  2. Make sure the air intake area (bottom) is not obstructed in any way
  3. Insert male end of power cord into grounded circuit
  4. Press RED POWER BUTTON, unit will start, press “+” or “-“ to switch speed “HIGHER” or “LOWER”
  5. Unit should now be functioning and operational
When to Replace Your Filters

Your unit comes equipped with a Service Filters light on the control panel. When this light is
illuminated, it is recommened that you order new filters as soon as possible.
Reduced air flow is a common symptom of dirty filters.

My Motor Shuts Off

There are a couple of reasons why your motor may randomly turn off:

  • Possible Cause: Motor overheated, tripped on thermal cutout
  • Suggested Solution: Switch power off, unplug, wait till motor cools, replace filters/verify blockage.
  • Possible Cause: Motor/motor brushes past service life
  • Suggested Solution: Replace motor/motor brushes.

Filter Pads Quantity: Twenty (20)

Part Number: F069-82

Contact Us

10.39″ HEPA Cartridge Filter Quantity: One (1)

Part Number: F032

Replacement HEPA cartridge filter for your Quatro Air unit.