IVAC 2.C TWIN BRUSHLESS

Recommended Use

Part Number: 1-0052-4002

IVAC 2.C TWIN BRUSHLESS

Heavy-Duty – More than 4 hours a day

Automatic Self-Cleaning dust collector with powerful brushless motor – includes mill-specific interface cable and HEPA filter. Large debris capacity.

Suggested Accessories
  • HIGH EFFICIENCY PREMIUM BRUSHLESS motor technology delivers more airflow
  • Newly designed heavy-duty main filter for larger particle removal
  • Improved, more efficient self-cleaning system
  • HEPA Filter, 99.97% efficiency on sub-micron particles like fine zirconia dust in CAD/CAM milling
  • Operate the mill overnight while the filters clean themselves
  • Easy access to the motors and filters
  • AUTOFLOW: Set to lowest acceptable speed, motors will maintain airflow despite pressure increase
  • Temporary ON: Clean your mill while unit is in standby mode
  • Separate access doors: remove debris without having to access filter section
  • “OnLine Filter Cleaning” (Worry-free feature automatically cleans the main filter without operator assistance. Milling machine runs uninterrupted)
  • Alerts you when filters need replacement
  • Debris storage capacity of 5.0 US Gallons (19.0 litres)
  • Also included: Mill specific Auto Start-Stop cable & 6 ft suction hose
  • Optional: Silencer for noise suppression (#AA449), Foot-pedal/Hand-switch for 6 ft manual Start-Stop (#AA175/#AA375), Signal Splitter (#AA686) to operate unit with Auto-Signal AND Foot-Pedal (for quick and easy mill cleaning)
Specification Value
Dimensions (H x W x L): 25.5 x 15.75 x 19.5 in (65x40x50 cm)
Shipping Weight: 90 lb (41 kg)
Power: 100-120 V, 50/60 Hz, 9 A
Sound Level: 64 dB(A)
Filters: F315, F074

Learn how to get the most out of your Quatro Air unit and troubleshoot common problems. You can also download the owner’s manual for this unit for technical details and instructions.

Owner’s Manual

Quatro Air iVAC Twin Dust Collector Owner’s Manual

How to Set Up Your Unit for the First Time

Introduction

Congratulations! You are now owner of a Quatro Air iVAC Twin Dust Collector, an advanced effective purifier designed specifically for the human respiratory system. You can expect a noticeable improvement in air quality as the unit begins the process of reducing microscopic airborne particulate, dust, harmful gases, smoke, and pollen etc.

 

Safety Precaution

Keep all fastening hardware tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which filters are installed & replaced. All filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do not use any two-wire electrical prong adapters to defeat proper grounding. If servicing the unit, be careful not to touch the motor as soon as it has been turned off.

IMPORTANT: Ensure power supply is unplugged during maintenance or filter service

Pre Start-Up Checklist

  1. Upon arrival, inspect unit for either visible or concealed damage. Damage should be immediately reported to the transport company.
  2. All filters are present and are correctly installed prior use
  3. Labels and serial numbers are present for future identification
  4. Verify that power supply is compatible with equipment. Check the unit is plugged into a grounded receptacle

Start-Up

WARNING: Do not operate unit until you’ve confirmed all filters have been installed

  1. Place the unit in the desired area for use. Ensure all filters are installed (remove all plastic wrapping)
  2. Make sure the air intake area (bottom) is not obstructed in any way
  3. Insert male end of power cord into grounded circuit
  4. Press RED POWER BUTTON, unit will start, press “+” or “-“ to switch speed “HIGHER” or “LOWER”
  5. Unit should now be functioning and operational
When to Replace Your Filters

Your unit comes equipped with a Service Filters light on the control panel. When this light is illuminated, it is recommended that you order new filters as soon as possible.
Reduced air flow is a common symptom of dirty filters.

My Motor Shuts Off

There are a couple of reasons why your motor may randomly turn off:

Possible Cause: Motor overheated, tripped on thermal cutout
Suggested Solution: Switch power off, unplug, wait till motor cools, replace filters/verify blockage.
Possible Cause: Motor/motor brushes past service life
Suggested Solution: Replace motor/motor brushes.

4″ Main Filter

Part Number: F315

Quantity: One (1) 4″ replacement main filter for your Quatro Air unit.

2″ HEPA Filter 99.97%

Part Number: F074

Quantity: One (1) 2″ replacement HEPA filter for your Quatro Air unit.